Page 50 - Market Analysis Report of Optical Communications Field in China & Global market 2019
P. 50

͐ ͕ ͖ ͛ ͎

           Fig.3.Light transmittance test room                     Fig.5. Acid gas concentration tester













                                                                   Table 8. CPR rating





           Table 6 The bundled burning test of optical cable


                                                                 evaluated. The evaluation results are shown in Table 8.

                                                                 5.Conclusions
                                                                 This paper can be concluded by comparing the test results
                                                                 of three design schemes A, B and C: In the design process
                                                                 of the Flame-retardant air-blowing optical cable , the outer
                                                                 diameter of the cable is smaller, the outer diameter of the
                                                                 core is smaller, the loose tube PBT material and the gel
                                                                 are obtained, The corresponding reduction in the amount
                                                                 of use will reduce the overall amount of smoke emitted
                                                                 by the cable and increase the light transmittance of the
                                                                 cable; The greater the outer wall thickness of the cable,
           Fig.4.CPR large-scale combustion test device          the better the flame retardant performance of the cable.
                                                                 However, the increase in the thickness of the outer wall of
                                                                 the cable leads to an increase in cable weight, a decrease
                                                                 in the overall toughness of the cable, and a decrease in
                                                                 air blowing performance. Under the outer diameter of the
                                                                 same cable, increase the size of the reinforcement, which
                                                                 can appropriately mention the toughness of the cable
                                                                 and optimize the air blowing performance of the cable;
                                                                 Therefore, it is very important to rationally design the
                                                                 structure of the optical cable, so that the optical cable can
                                                                 meet the corresponding CPR classification standard and
                                                                 meet the air blowing distance requirements of different
                                                                 laying scenarios.

                                                                 6. Acknowledgments
           Table 7. Acid gas concentration test                  The authors would like to express gratitude to everyone
                                                                 who cooperated in the completion of this paper and
                                                                 manufacture of the production. Thanks to our R&D
                                                                 Engineering and Quality teams for designing, tracking and
                                                                 testing the samples.

                                                                 7. References
                                                                 [1]  Bingyan Chen: Design and manufacture of optic fiber and
         4.3.5 CPR rating                                               fiber optic cable [M]. Zhejiang University Press, 2016
         According  to  the  EN13501-6  cable  product  grade    [2]  YD/T1118.1-2001: Secondary coating materials used for
         classification standard, the three schemes A, B and C are          optical fiber—part 1: Polybutylene terephthalate.